AS-2/CHE/CHESK

Trifurcation kit for CHE, CHESK and CTS, CTKS
for 3-core polymeric cables up to 36 kV
Art. no.
253902
More Information
Product family Trifurcation kit
Product family Trifurcation kit
Main description Trifurcation kit for CHE, CHESK and CTS, CTKS
Sub description for 3-core polymeric cables up to 36 kV
Family description The trifurcation kit allows the installation of products designed for 1-core-cable on 3-core-cable, suitable for different cable types.
Characteristics Quick, safe and easy assembly, Superior electrical properties, High mechanical strength
Applications Indoor/Outdoor, Protection against dust and moisture
More Information
Voltage levels U0/U (Um) 6/10 (12) kV - 19/33 (36) kV
Applicable for CHE-I, CHESK-I 12 kV
Nominal cross section 12 kV min 95 mm²
Nominal cross section 12 kV max 240 mm²
Diameter over core insulation after removal of the outer conductive layer min 17,3 mm
Applicable for CHE-F 12 kV
Nominal cross section 12 kV min 150 mm²
Nominal cross section 12 kV max 400 mm²
Diameter over core insulation after removal of the outer conductive layer min 19,9 mm
Applicable for CHESK-I 24 kV
Nominal cross section 24 kV min 25 mm²
Nominal cross section 24 kV max 150 mm²
Diameter over core insulation after removal of the outer conductive layer min 17,3 mm
Applicable for CHESK-F 24 kV
Nominal cross section 24 kV min 95 mm²
Nominal cross section 24 kV max 240 mm²
Diameter over core insulation after removal of the outer conductive layer min 19,9 mm
Applicable for CHE-I, CHE-F 24 kV
Nominal cross section 24 kV min 25 mm²
Nominal cross section 24 kV max 150 mm²
Diameter over core insulation after removal of the outer conductive layer min 17,3 mm
Applicable for CHE-I, CHE-F 24 kV
Nominal cross section 24 kV min 70 mm²
Nominal cross section 24 kV max 240 mm²
Diameter over core insulation after removal of the outer conductive layer min 19,9 mm
Applicable for CHE-I, CHE-F 24 kV
Nominal cross section 24 kV min 120 mm²
Nominal cross section 24 kV max 300 mm²
Diameter over core insulation after removal of the outer conductive layer min 23,1 mm
Applicable for CHESK-I 36 kV
Nominal cross section 36 kV min 16 mm²
Nominal cross section 36 kV max 95 mm²
Diameter over core insulation after removal of the outer conductive layer min 19,9 mm
Applicable for CHESK-F 36 kV
Nominal cross section 36 kV min 50 mm²
Nominal cross section 36 kV max 240 mm²
Diameter over core insulation after removal of the outer conductive layer min 23,1 mm
Applicable for CHE-I, CHE-F 36 kV
Nominal cross section 36 kV min 35 mm²
Nominal cross section 36 kV max 70 mm²
Diameter over core insulation after removal of the outer conductive layer min 19,9 mm
Applicable for CHE-I, CHE-F 36 kV
Nominal cross section 36 kV min 50 mm²
Nominal cross section 36 kV max 150 mm²
Diameter over core insulation after removal of the outer conductive layer min 23,1 mm
Applicable for CHE-I, CHE-F 36 kV
Nominal cross section 36 kV min 150 mm²
Nominal cross section 36 kV max 240 mm²
Diameter over core insulation after removal of the outer conductive layer min 27,3 mm
More Information
Delivery scope Heat shrinkable tubes, Spreader cap, Mastic tape, Copper braid tube, Screw cable lug, Assembly material, Assembly instructions
Shelf life description Unlimited shelf life
Country of origin Germany
Customs tariff number 39173900
EAN/GTIN 4010311136295
Alternate quantity 1 1
Alternative unit of measure Piece Bag1
Base quantity 1 1
Base unit of measure Piece Piece
Lenght (mm) 1081 1081
Width (mm) 283 283
Height (mm) 115 115
Net weight (kg) 1,59 1,59
Gross weight (kg) 1,59 1,59